MiniPID 2 HS Sensor Deployment Guidelines


PID responses greater than ~3000 ppb cause a saturated HS MiniPID signal.  VOC readings >3000 ppb can be expected in some commonly encountered  environments, for example:

• In domestic environments on occasion of heavy release of volatiles, such as from paints and varnishes, use of certain cleaning fluids or during cooking. 

By contrast, clean rural air delivers a PID response of less than 100 ppb.  In reasonably ventillated interior spaces at 20 to 25 oC (68 to 77 o F), 200 to 400 ppb is typical. However, these ambient levels increase significantly in the absence of ventillation and at higher temperatures